您好,欢迎来到绿色节能环保网 [请登录] [免费注册]
当前位置: 首页 » 资讯 » 企业新闻 > 新品发布 » 正文

三氯甲烷/氯仿气体检测管137LA 检测范围0.5-30pp

发布时间: 来源:上海乐丁电子科技有限公司

....
三氯甲烷/氯仿气体检测管137LA 检测范围0.5-30ppm的详细介绍
氯甲烷/氯仿气体检测管137LA 检测范围0.5-30ppm,三氯甲烷(氯仿)检测管137CHCl3 Chloroform相关产品. 石脑油气体检测管价格NO.106 106 165LGastec便携式气体检测管乙二醇检测管(HOCH2CH2OH)气体检测管是用来测定某种气体在某一环境中所含浓度的简易检测装置。

三氯甲烷/氯仿气体检测管137LA 检测范围0.5-30ppm

三氯甲烷/氯仿气体检测管137LA 检测范围2-12ppm

Performance
Measuring Range
0.5to2ppm 2to12ppm 12to30ppm
Number of Pump Strokes
4 2 1
Correction Factor
0.25 1 2.5
Sampling Time 2 minutes per pump stroke
Detecting Limit 0.2 ppm (n=4)
Colour Change White → Pale purple
Reaction Principle CHCl3 + I2O5 + H2S2O7 → Cl2
Cl2 + (CH3C10H5NH2)2→ Pale purple products
Coefficient of Variation 10% (for 2 to 4 ppm), 5% (for 4 to 12 ppm)
Shelf Life 1 Year
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
Possible coexisting substances and their interferences
Substance Concentration Interference Change colour by itself to
Chlorine   No No
Bromine   No No
Iodine   No No
Unsaturated halogenated HCs   + Pale purple
Saturated halogenated HCs   + Pale purple
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
10 ppm - -
 
仕様
目盛範囲: 2~12ppm〔基準n=2〕
測定範囲: 0.5〔n=4〕~30ppm〔n=1〕
吸引回数〔n〕: 4,2〔基準〕,1
1回(100ml)の吸引時間: 2分
検知限度: 0.2ppm〔n=4〕
変色: 白色→淡紫色
温?湿度補正: 温度
有効期限: 1年(冷蔵庫保存)
指示精度: CV=5~10%
(CV:変動係数=σ:標準偏差÷平均値×100)
干渉ガス
ガス名 共存の場合の濃度と結果 単独の場合
塩素   影響しない 変色しない
臭素   影響しない 変色しない
ヨウ素   影響しない 変色しない
不飽和ハロゲン化炭化水素   +誤差 淡紫色に変色
飽和ハロゲン化炭化水素   +誤差 淡紫色に変色
校正用ガス ガス拡散管法
許容濃度 管理濃度 TWA STEL 爆発範囲
3ppm 3ppm 10ppm -- --



(官方微信号:chinajnhb)
(扫一扫,节能环保信息随手掌控)
免责声明: 本文仅代表作者个人观点,与 绿色节能环保网 无关。其原创性以及文中陈述文字和内容未经本站证实, 对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不作任何保证或承诺,请读者仅 作参考,并请自行核实相关内容。